47 mm or more
120 m
m or more
1 Installation
plate
Wall
Do not allow the drain hose to
get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be
connected to the left, rear left,
rear right, bottom right or
bottom left.
Insulate the refrigerant pipes
separately with insulation, not
together.
120 mm or more
For the rear left and left piping
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Rear
left
Left
Bottom left
Rear
right
Bottom right
2 Wireless remote control
5Sasa-zeolite
6Bio-enzyme &
4 Remote control holder
8 Pan head
wood screw
100 mm or more
45 mm or more
4
0
0
m
m
o
r
m
o
r
e
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
6
0
0
m
m
o
r m
o
re
Extension
drain hose
(Not available,
provided by
installer)
4
0
0
m
m
o
r
m
o
r
e
100 mm or more
600 mm or more
45 mm or more
Extension drain hose
(Not available, provided
by installer)
600 mm or more
6
0
0
m
m
o
r m
o
re
07 Class
10 Class
6 mm thick heat resisting
polyethylene foam
The auxiliary piping can be
connected to the left, rear left,
rear right,
right, bottom right
or bottom left.
Rear
left
Left
Bottom left
Right
Rear right
Bottom
right
33
33
3 Batteries
22
22
2 Wireless remote control
Cover
Before installing the
wireless remote control
With the remote control cover
open, load the batteries supplied
polarity.
correctly observing their
·
– 36 –
FILE NO. SVM-06037
8-2. Installation Diagram of Indoor and Outdoor Units