– 4 –
FILE NO. SVM-06037
RAS-07GKHP-E RAS-07GKP-E RAS-07GKPX
RAS-07GAH-E RAS-07GA-E RAS-07GAX
ITEM Cooling Heating Cooling Cooling
Capacity
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.00 2.05 2.00 2.05 2.10 2.15 2.10 2.15
Phase 1∅
Power source V 220 − 240
Hz 50
Power consumption kW 0.61 0.68 0.54 0.59 0.58 0.62 0.58 0.62
Power factor % 98 97 98 96 98 96 98 96
Running Indoor A 0.15
current Outdoor A 2.69 2.77 2.35 2.40 2.55 2.55 2.55 2.55
Starting current A 14 13
Moisture removal lit/h 0.8
Noise Indoor (H/M/L) dB 38/33/28
Outdoor (220-240V) dB
Refrigerant
Name of refrigerant R-22
Rated amount kg 0.60 0.63
Refrigerant control Capillary tube
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
m 5
difference
INDOOR UNIT RAS-07GKHP-E RAS-07GKP-E RAS-07GKPX
Height mm 250
Dimensions Width mm 740
Depth mm 185
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 490 490 510
Airflow volume Medium fan m
3
/h 430 450 430
Low fan m
3
/h 350 370 350
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07GAH-E RAS-07GA-E RAS-07GAX
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg 28 27
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1280 1360 1280 1360 1280 1360 1280 1360
Fan motor output W 20
Compressor
Model PH108X1C-4DZDN2
Output W 605
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 15 ~ 43
MODEL
44
45 45
46
44 45
44
45
∅
∅
21 ~ 43