AIR CONDITIONER (SPLIT TYPE)
INSTALLATION MANUAL
Indoor unit
RAS-10, 13, 16PKVSG-E
Outdoor unit
RAS-10, 13, 16PAVSG-E
1118350131
R32
ENGLISH
ESPAÑOL
FRANÇAIS
ITALIANO
DEUTSCH
PORTUGUÊS
POLSKI
ČESKY
ΕΛΛΗΝΙΚΑ
00_1118350131-Cover.indd 100_1118350131-Cover.indd 1 2/6/2560 BE 11:12 AM2/6/2560 BE 11:12 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-10PKVSG-E and is the answer not in the manual?

Toshiba RAS-10PKVSG-E Specifications

General IconGeneral
TypeSplit System
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR32
Power Supply220-240V, 50Hz
Indoor Unit Dimensions (WxHxD)798 x 293 x 230 mm
Indoor Unit Weight9 kg

Summary

Safety Precautions

Power Supply Cord and Connecting Cable Standards

Power supply cord must meet H07RN-F or 60245 IEC66 for public use.

Disconnecting from Main Power Supply Requirements

Use a circuit breaker or switch with at least 3mm contact separation for disconnection.

Danger Warnings

General Danger Warnings for Installation and Operation

Covers qualified personnel, electrical safety, gas hazards, overheating, and refrigerant handling.

Warning Precautions

Warning Precautions for Unit Installation and Electrical Work

Includes not tampering with safety guards, installation load, earthing, and wiring regulations.

Refrigerant and Piping Safety

Refrigerant Type and Piping Specifications for R32

Use specified R32 refrigerant, pipes, flare nuts, and tools; thickness >0.8mm.

Flare Connection and Leak Detection Procedures

Flare connections must be outdoors; confirm no refrigerant leakage after installation.

General Cautionary Notes

Reporting to Local Power Supplier

Mandatory Reporting of Appliance Installation

Installation must be reported to the local power supplier before commencement.

Indoor Unit

Cutting a Hole and Mounting Installation Plate

How to Connect Remote Controller for Wire Operation

Piping and Drain Hose Installation

Indoor Unit Fixing

Outdoor Unit

Precautions for Installation in Regions with Snowfall and Cold Temperatures

Guidance on protecting the unit from snow and cold, including using holding frames.

Refrigerant Piping Connection

Flaring Procedure for Refrigerant Pipes

Instructions for cutting, flaring, and checking the projection margin of pipes.

Tightening Connection for Refrigerant Pipes

Steps for tightening flare nuts using fingers, spanner, and torque wrench.

Tightening Torque of Flare Pipe Connections

Importance of Correct Tightening Torque for R32 Flare Connections

Emphasizes firm tightening due to higher R32 operating pressure to prevent leaks and damage.

Evacuating

Key Points for Piping Work During Evacuation

Essential steps including removing moisture, tightening, evacuation, leak checks, and valve operation.

Using a Vacuum Pump for Air Purge

Procedure for connecting and operating a vacuum pump to remove air from the system.

Electrical Works

Wiring Connection

Power Supply and Connecting Cable Connection

Power Supply Input Wiring Diagram

Caution

Appendix

Work Instructions for Reusing Existing R22/R410A Pipes for R32

Guidelines and warnings for updating existing piping for new refrigerant systems.

Basic Conditions Needed to Reuse Existing Pipes

Restrictions for Use of Existing Pipes

Cases Where Existing Pipes Cannot Be Reused

Lists conditions like scratches, thinness, contamination, or compressor history that prevent reuse.