– 47 –
Table 9-4-2 Approximate value of the sensor (thermistor) resistance (TA, TC)
(= k)
9-4-3. How to Reduce the Operation Time of
the Anti-Restart Timer
Attach the diode (1S1555 or equivalent) to the rivet
inside the unit through holes on the rear of the
wireless remote control unit.
Push the START/STOP button to start operation
with the diode attached.
Fig. 9-4-1
Temperature
Sensor
Themo Sensor
0°C
35.8
10°C
20.7
20°C
12.6
25°C
10.0
30°C
7.92
Timer short diode