– 4 –
FILE NO. SVM-03004(1)
MODEL RAS-10UKHP-E2 / RAS-10UAH-E2 RAS-10UKP-E2 / RAS-10UA-E2
ITEM Cooling Heating Cooling
Capacity
220 V 240 V 220 V 240 V 220 V 240 V
kW 2.70 2.75 3.12 3.15 2.65 2.70
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption kW 1.00 1.05 0.89 0.91 0.80 0.85
Power factor % 95 92 94 91 96 94
Running Indoor A 0.15
current Outdoor A 4.65 4.60 4.15 4.00 3.65 3.60
Starting current A 19 16
Moisture removal lit/h 1.2
Noise
Indoor (H/M/L) dB 39/33/26
Outdoor (220 – 240 V) dB 47 49 47 49 44 45
Refrigerant
Name of refrigerant R22
Rated amount kg 0.76 0.68
Refrigerant control Capillary tube
Gas side size mm ∅9.52
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
m5
difference
INDOOR UNIT RAS-10UKHP-E2 RAS-10UKP-E2
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 570 610 630
Air volume Medium fan m
3
/h 460 520 490
Low fan m
3
/h 340 400 370
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10UAH-E2 RAS-10UA-E2
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 31 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2030 2150 2030 2150 1740 1850
Fan motor output W 18 20
Compressor
Model PH120T1-4C 2PS146D5AB02
Output W 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24 15 ~ 43