– 5 –
FILE NO. SVM-03004(1)
MODEL
RAS-13UKPX2 / RAS-13UAX2 RAS-10UKPX2 / RAS-10UAX2
ITEM Cooling
Capacity
220 V 240 V 220 V 240 V
kW 3.70 3.75 2.65 2.70
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption kW 1.24 1.28 0.80 0.85
Power factor % 98 95 97 95
Running Indoor A 0.15
current Outdoor A 5.60 5.45 3.60 3.58
Starting current A 24 16
Moisture removal lit/h 2.0 1.2
Noise
Indoor (H/M/L) dB 41/35/31 39/33/26
Outdoor dB 47 48 44 45
Refrigerant
Name of refrigerant R22
Rated amount kg 0.80 0.65
Refrigerant control Capillary tube
Gas side size mm ∅12.70 ∅9.52
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 15*
1
10*
1
(One way)
Maximum height
m6 5
difference
INDOOR UNIT RAS-13UKPX2 RAS-10UKPX2
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 630 630
Air volume Medium fan m
3
/h 550 490
Low fan m
3
/h 460 370
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13UAX2 RAS-10UAX2
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 35 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2030 2150 1740 1850
Fan motor output W 30 20
Compressor
Model PH160T2-4LH2 PH102T1-4CH
Output W 1100 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43