– 14 –
FILE NO. SVM-03001
4-5. Outdoor Unit (RAS-10UA-ES2, RAS-10UA-AS2)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PA108X1T-4FZ1 Winding resistance () C-R C-S
(at 20°C) 3.89 4.51
Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-20B Winding resistance () Red-Black White-Black
(at 20°C) 387.3 466.2
3
Running capacitor
DS451155BPQC AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
DS371256CPNB AC 370V, 25µF
(for compressor)