– 4 –
FILE NO. SVM-03001
MODEL RAS-10UKHP-ES2, AS2 RAS-10UKP-ES2, AS2
RAS-10UAH-ES2, AS2 RAS-10UA-ES2, AS2
ITEM Cooling Heating Cooling
Capacity
220V 240V 220V 240V 220V 240V
kW 2.70 2.70 2.90 2.96 2.70 2.70
Phase 1∅
Power source V 220 – 240
Hz 50
Power consumption kW 0.82 0.84 0.78 0.82 0.82 0.84
Power factor % 98 97 97 96 98 97
Running Indoor A 0.15
current Outdoor A 3.65 3.45 3.50 3.40 3.80 3.60
Starting current A 18
Moisture removal lit/h 1.2
Noise
Indoor (H/M/L) dB 39/33/26
Outdoor (220-240V) dB 47 49 47 49 46 47
Refrigerant
Name of refrigerant R410A
Rated amount kg 0.72 0.65
Refrigerant control Capillary tube
Gas side size mm ∅9.52
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
m5
difference
INDOOR UNIT RAS-10UKHP-ES2, AS2 RAS-10UKP-ES2, AS2
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 570 610 630
Air volume Medium fan m
3
/h 460 520 490
Low fan m
3
/h 340 400 370
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10UAH-ES2, AS2 RAS-10UA-ES2, AS2
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 35 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2030 2150 2030 2150 1740 1850
Fan motor output W 30 20
Compressor
Model PA108X1T-4FZ1
Output W 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24 15 ~ 43