EasyManua.ls Logo

Toshiba RAS-10UKPX2 - Ras-10 Ukpx2; Ras-10 Uax2

Toshiba RAS-10UKPX2
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
FILE NO. SVM-03004(1)
5-6.RAS-10UKPX2 / RAS-10UAX2
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH102T1-4CH
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39 m
(Connecting pipe)
9.52
0.49 m
(Connecting pipe)
6.35
T1
P
Refrigerant
R22 : 0.65 kg.
Evaporator
Capillary tube
1.5x1000s
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.53 11.0 High 27/19 35/24
Cooling Overload 0.62 16.0 High 32/23 43/26
Low temperature 0.48 5.0 Low 21/15 21/15
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
50Hz
Note
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)

Table of Contents

Related product manuals