EasyManua.ls Logo

Toshiba RAS-10UKPX4 - Ras-07 Ukp-E4; Ras-07 Ua-E4, Ras-07 Ukpx4; Ras-07 Uax4

Toshiba RAS-10UKPX4
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
5-6. RAS-07UKP-E4 / RAS-07UA-E4
RAS-07UKPX4 / RAS-07UAX4
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Cooling
Standard 0.59 13.5 High 27/19 35/24
Overload 0.69 18.0 High 32/23 43/26
Low temperature 0.32 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
PH108X1C-4DZDN2
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39m
(Connecting pipe)
9.52
0.49m
(Connecting pipe)
6.35
T1
P
Refrigerant
R-22 : 0.57 kg.
Heat exchanger
Capillary tube
1.5x1200S
FILE NO. SVM-05001

Table of Contents

Related product manuals