EasyManua.ls Logo

Toshiba RAS-10YKH-E - 9-3-3. Outdoor Unit does not Operate

Toshiba RAS-10YKH-E
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
Shut off the power supply
from AC outlet once and
turn it on after 5 seconds.
Does the OPERATION lamp blink?
Does the power turn on by
pushing the [START/STOP] button
of the remote control?
Is cable connection
between indoor and outdoor
units correct?
Check items as following procedure
in 9-3-4, 9-3-5, 9-3-6.
Replace the
P.C. board.
See Power can not be turned on.
Relays (RY01, RY02)
or IC31 or IC30 is failure.
Correct cabling between
indoor and outdoor units.
NO
NO
NO
NO
YES
YES
YES
YES
See Power can not be turned on.
Is AC 220240V
supplied between terminal block
1 - 2 ?
9-3-3. Outdoor Unit does not Operate