EasyManua.ls Logo

Toshiba RAS-10YKV-E - Performance and Characteristics; Protection and Power Failure

Toshiba RAS-10YKV-E
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
More user manuals on ManualsBase.com
20
6-2. Operation Data
<Cooling>
<Heating>
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
Temperature
condition (°C)
Heat exchanger
pipe temp.
Indoor Outdoor
Model name
Standard
pressure
P (MPa)
T1 (°C) T2 (°C)
Indoor fan
mode
Outdoor fan
mode
Compressor
revolution
(rps)
10YKV-E 0,8 to 1,0 9 to 11 42 to 44 High High 56
27/19 35/
13YKV-E 0,8 to 1,0 8 to 10 46 to 48 High High 85
Temperature
condition (°C)
Heat exchanger
pipe temp.
Indoor Outdoor
Model name
Standard
pressure
P (MPa)
T1 (°C) T2 (°C)
Indoor fan
mode
Outdoor fan
mode
Compressor
revolution
(rps)
10YKV-E 3,5 to 3,7 42 to 44 2 to 4 High High 70
20/ 7/6
13YKV-E 2,5 to 2,7 50 to 52 0 to 3 High High 97

Other manuals for Toshiba RAS-10YKV-E

Related product manuals