<Cooling> <Heating>
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90 100 110 120
Compressor Speed (rps)
Current (A)
0
1
2
3
4
5
6
7
8
9
0 102030405060708090100110120
Compressor Speed (rps)
Current (A)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C
Air Flow : High
Pip Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Air Flow : High
Pip Length : 5m
Voltage : 230V
RAS-10N3KV2-A
RAS-10N3KV2-A
Capacity Variation Ratio According to Temperature (RAS-10N3KV2-A)
<Cooling>
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Outdoor temp. (℃)
Capacity ratio (%)
RAS-10N3KV2-A
Conditions
Indoor:DB27℃/WB19℃
Indoor air flow:High
Pipe length:5m
Capacity ratio:100%=
2.5kW(RAS-10N3KV2-A)
<Heating>
0
20
40
60
80
100
120
-15 -10 -5 0 5 10
Outdoor temp. (℃)
Heating Capacity ratio (%)
RAS-10N3KV2-A
Condition
Indoor:DB20℃
Indoor air flow:High
Pipe length:5m
Voltage : 230V
Voltage : 23
0V
FILE NO. SVM-13001
– 7 –
Operation Characteristic Curve (RAS-10N3KV2-A)