Operation Characteristic Curve (RAS-13,16N3KV2-A)
<Cooling> <Heating>
Capacity Variation Ratio According to Temperature (RAS-13,16N3KV2-A)
7
FILE NO. SVM-13001
0
1
2
3
4
5
6
7
8
9
0 102030405060708090100110120
Current (A)
Compressor Speed (rps)
0
1
2
3
4
5
6
7
8
9
0 102030405060708090100110120
Current (A)
Compressor Speed (rps)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C
Air Flow : High
Pipe Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Air Flow : High
Pipe Length : 5m
Voltage : 230V
RAS-13N3KV2-A
RAS-16N3KV2-A
RAS-13N3KV2-A
RAS-16N3KV2-A
<Coolin
g
><
Heatin
g
>
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio (%)
Outdoor temp. (
o
C)
0
20
40
60
80
100
120
-15 -10 -5 0 5 10
Capacity ratio (%)
Outdoor temp. (
o
C)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C
Air Flow : High
Pipe Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Air Flow : High
Pipe Length : 5m
Voltage : 230V
Capacity ratio :100%
4.2kW (RAS-13N3KV2-A)
5.3kW (RAS-16N3KV2-A)
Capacity ratio :100%
3.4kW (RAS-13N3KV2-A)
4.4kW (RAS-16N3KV2-A)
RAS-13N3KV2-A
RAS-16N3KV2-A
RAS-13N3KV2-A
RAS-16N3KV2-A