– 19 –
FILE NO. SVM-05027
5. SPECIFICATION OF ELECTRICAL PARTS
5-1. Indoor Unit (For 13NKV)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150°C thermo fuse
2 Thermo. sensor (TA-sensor) ——— 10 kΩ at 25°C
3 AC-AC transformer (T01) TT-10 187 - 276V, 6VA
4 Microcomputer
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27 µH, AC 0.64A
7 Diode (DB01) KBP06M 1.5A, 420V
8 Capacitor (C50) 2200µF, 35 V
9 Fuse (F01) BET 3.15A, 250VAC T3.15A, 250 V
10 Regulator IC (IC08) NJM7812 12VDC, 1.5A max
11 Regulator IC (IC11) NJM7805 5VDC, 1.5A max
12 Varistor (R21, R109) 15G561K 560V
13 Louver motor DC 12V
LXV35VB2200MJ20
µPD780024AGK
24BYJ48
No. Parts name Type Specifications
1 Fan motor (for indoor) ICF-340-30-2 DC 340 V, 30 W
2 Thermo. sensor (TA-sensor) ——— 10 kΩ at 25°C
3 DC-DC transformer (T01) SWT-70 DC 390 V, Secondary DC 15 V, 12 V, 7 V
4 Microcomputer µPD780024AGK
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01 SS11V-06270 27mH, AC 0.6A
7 Diode (DB01) D3SBA60 4A, 600 V
8 Capacitor (C03) KMH450VSSN120M25C 120µF, 450 V
9 Fuse (F01) FCU250V, 3.15A T3.15A, 250 V
10 Power supply IC (IC01) STR-L472
11 Varistor (R21, R109) 15G561K 560 V
12 Resistor (R01) RF-5TK4R7 4.7Ω, 5 W
13 Louver motor 24BYJ48
5-2. Incoor Unit (For 16NKV)
DC 12V