No. Parts name Model name Rating
1 SC coil L01 ADR2516-0R6TB 15A, 0.6mH
(Noise filter) L03 ADR2510-020 T4B 20A, 0.15mH
Primary side DC280V, Secondary
2 DC-DC transformer SWT-72
side 7.0 V x 1, 12V x 1, 17V x 2
3 Reactor CH-57-Z-T L=10mH, 16A x 2
4 Outside fan motor ICF-140-43-4 DC140V, 43W
5 Fan control relay
(Inverter attached) 10 k (25°C)
(TS sensor)
6
Discharge temp. sensor
(Inverter attached) 62 k (20°C)
(TD sensor)
7
Outside air temp. sensor
(Inverter attached) 10 k (25°C)
(TO sensor)
8
Heat exchanger temp.
(Inverter attached) 10 k (25°C)
sensor (TE sensor)
9 Terminal block (6P)
10 Fuse
For protection of switching power source 3.15A, AC 250 V
For protection of inverter input overcurrent 25A, AC 250 V
11 Electrolytic capacitor LLQ2G761KHUBTF 760µF, DC 400 V x 3 pieces
12 IGBT GT20J321 20A, 600 V
13 Compressor DA89X1F-23F 3-phases 4-poles 1100 W
15
Rectifier
D25XB60-4001
20A, 600V
JXO-6B
30A, 600 VAC