6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. ype SpecificatType
1 Fan Motor (for indoor)
RAS-05, 07, 10, 13
SJM-240-25 AC 220~240V, 25W
RAS-16
SJM-240-35 AC 220~240V, 35W
2 Room temp. sensor (TA-sensor) (-) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) (-) 10kΩ at 25°C
4
Louver motor 24BYJ48A-080 Output (Rated) 4 phase, DC12V
Parts name
No. Type name Specifications
1 Compressor RAS-05, 07 NX66F0F-20D 3-Phases (6-Poles) ; 630W
RAS-10, 13 NX89F0F-20D 3-Phases (6-Poles) ; 790W
RAS-16
KSN108D22UFZ
3-Phases (6-Poles) ; 840W
2 Fan Motor WDF-340-A43-1 DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil PQ-M10012-000313 DC 12V
4 4-Way valve coil DXQ-939 AC 220-240V
5 Reactor RAS-16 CH-69-Z-T L = 19mH, 10A
6 Suction temp. sensor (TS sensor) (Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor (TD sensor) (Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor (TO sensor) (Inverter attached)
9 Heat Exchanger temp. sensor (TE sensor) (Inverter attached)
10kΩ at 25°C
10 Terminal block (5 poles) JXO-5B
AC 250V, 20A
Parts name
10kΩ at 25°C
www.ampair.co.uk | sales@ampair.co.uk