10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
Before installing the wireless remote controller
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.
3 Batteries
2 Wireless remote controller
AC
L
2
3
6
4
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
1
Batteries
Flat head
wood screw
Remote control
holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension drain hose
(Not available, provided
by installer)
Shield pipe
(Attach to the front panel.)
Air ¿ lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
C mm or more
F mm or more
E mm or more
D mm or more
C mm or more
Remark :
Detail of accessory and installation parts can see in the
accessory sheet.
Some pictures might be different from the actual parts.
RAS-05, 07, 10, 13BAVG-E
RAS-16BAVG-E
C
600 600
D 400 600
E45 100
F 100 100
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The À are connection should be installed
outdoors.
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
FILE NO. SVM-16030