5. ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY mode)
Press
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the
set temperature will decrease.
6. TEMPORARY OPERATION
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or stop
without using the remote control.
Operation mode is set on AUTOMATIC
operation, preset temperature is 25°C
and fan operation is automatic speed.
7. AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the unit
must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 secpmds)
Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the
operation. (3 beep sound but OPERATION lamp does not blink)
2. Press
to rise or decrease the
brightness in 4 levels.
8. DISPLAY LAMP BRIGHTNESS ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
for 3 seconds until brightness level ( , ,
or ) is shown on remote controller display.
Remote control
LCD
Operation display
Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the operation lamp
is turned off.
50%
All lamps are turned off.
All turned off
and , the lamp illuminates for 5 seconds before
● In the examples of
going off.
FAN