11-10. How to setting the CLEAN OPERATION cancel
11-10-1.
Self-Cleaning
function
Self-Cleaning diagram
Operation display ON OFF OFF
FCU fan
ON
OFF
ON
rpm is depend on presetting. (500RPM)
FCU louver OPEN OPEN (12.7º) CLOSE
Timer display ON
ON or OFF
depend on presetting of timer function.
ON or OFF
depend on presetting of timer function.
Compressor OFF OFF
ON or OFF
depend on presetting per room temperature.
CDU fan
OFF OFF
ON or OFF
depend on presetting per room temperature.
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning mode
operate 20 mins.
Automatically turn-off.
Operation time
Turn off by remote controller or
timer-off function.
How to set/cancel Self-Cleaning function
To set/cancel the Self-Cleaning function, proceed as
follows:
11-10-2.
Self-Cleaning function release
ON
Operation LED
Self-cleaning
flash 1 Hz
function
Timer LED
Flash 1 Hz
OFF
flash 1 Hz
not flash
ON
OFF
ON
OFF
S
etting diagnosis code "06" on r
emote controller
(
See detail of setting diagnosis code in 11-4-1)
Take the remote controller to direction of LED
display on air conditioner, press [ TEMP ] of
the remote controller (Fig. 11-10-2) 1 time
to send the code "07", then air conditioner will
shutdown automatically. Also, LED display will
show flash follow the able below.
Turn on air conditioner again by remote controller
to confirm setting.
T
urn on the poert supply to air con
ditioner,
after that press [RESET] button on air condition
e
r
1 time to turn on the air conditioner (The LED
d
i
splay will show in green color) (Fig. 11-10-1)
Note) Table above will show current status of
Self-Cleaning function
Set or Cancel Self-Cleaning function by push
the RESET button at LED display.
When setting is changed, the sound warning will
alarm "Beep". The setting is changed following
below.
Fig. 11-10-1
OPERATION /
RESET Button
FILE NO. SVM-16030
- 97 -
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk