4-3. Outdoor Unit (RAS-18NA-E, RAS-18N2AX)
– 14 –
FILE NO. SVM-0600
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH400X3CS-4KT1 Winding resistance (Ω) C-R C-S
(at 20°C) 1.13 2.10
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) FG-240-42A-1 Winding resistance (Ω) Red-Black White-Black
(at 20°C) 128 126
3
Running capacitor
451405L AC 450 V, 4.0µF
(for fan motor)
4
Running capacitor
RS44B506K0218S AC 440 V, 50µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 kΩ at 25°C / 50 kΩ at 25°C
7 Magnetic contactor A35 220 − 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V
4-4. Outdoor Unit (RAS-24NAH-E)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH340X3C-4KT1 Winding resistance (Ω) C-R C-S
(at 20°C) 1.46 2.47
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) WLF-240-42A-1 Winding resistance (Ω) Red-Black White-Black
(at 20°C) 188 289
3
Running capacitor
451205L AC 450 V, 2.0µF
(for fan motor)
4
Running capacitor
RS44B506U0218S AC 440 V, 50µF
(for compressor)
5 Magnetic contactor CLK-26J 220 – 240 V, 50 Hz