Toshiba RAS-18N2AX - 5-3. RAS-24 UFHP-E5; RAS-24 NAH-E Cycle Diagram

Toshiba RAS-18N2AX
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-06006
18
Standard 0.32 43.5 High 20/ 7/6
Heating High temperature*1
0.51 58.9 Low 27/ 24/18
Low temperature
0.
18 38.4 High 20/––
10/10
Standard
0.4
3 11.0 High 27/19 35/24
Cooling High temperature 0.
59 15.7 High 32/23 43/26
Low temperature
0.3
4 1.4 Low 21/15 21/15
5-3. RAS-24UFHP-E5 / RAS-24NAH-E
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
*1 : During heating overload, the high temperature limit control operation is included.
50Hz
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Evaporator
Indoor unit
Multi blade fan
Cooling
Heating
4-way valve
Heating
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
2.0x1400S
PH400X3CS-4KT1
Accumulator
Cooling
Heating
Mark ( ) means check points of Gas Leak
O.D.:6.35 mm
Packed valve
0.49m
(Connecting pipe)
6.35 mm
T
Capillary tube
1.0x1200S
Refrigerant
R-22 2.00kg
Packed valve
(15.88)
P
O.D.:15.88 mm
0.39m
(Connecting pipe)
15.88 mm
15.88 mm
0.39m
(Flexible pipe)
Cooling
Heating
(∅6.35)