Toshiba RAS-18N2AX - 8-6. Remote Control and Wiring Setup

Toshiba RAS-18N2AX
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power source
Maximum running
current
Plug socket &
fuse rating
Power cord
50 Hz, 220 240 V Single phase
16A 18A
20A
4 mm
2
(H07RN-F or 245 IEC 66) or 3.5 mm
2
(AWG-12)
18 Class
24 Class
FILE NO. SVM-06006
46
<Packed valve handling precautions>
Open the valve stem all the way out; but do not try to
open it beyond the stopper.
Securely tighten the valve stem cap with torque in
the following table:
Hexagonal wrench : A (Unit : mm)
Fig. 8-5-7
18 Class 24 Class
TO CHARGE REFRIGERANT
Gas side
(15.88 mm.)
Gas side
(12.70 mm.)
Liquid side
(6.35 mm.)
Service port
4 mm.
4 mm.
Same as
Gas side
Pipe side ATightening torque
65 to 80 N·m
(6.5 to 8.0 kgf·m)
50 to 62 N·m
(5.0 to 6.2 kgf·m)
16 to 18 N·m
(1.6 to 1.8 kgf·m)
9 to 10 N·m
(0.9 to 1.0 kgf·m)
No need to charge
refrigerant
Need to charge
refrigerant
15 m or less
Over 15 m up to
20 m (20g/m)
15 m or less
Over 15 m up to
25 m (30g/m)
A
Hexagonal wrench
is required.
8-5-4. Wiring connection
1. Remove the electric parts cover from the outdoor
unit.
2. Connect the connecting cable to the terminal as
identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.
3. When connecting the connecting cable to the
outdoor unit terminal, make a loop as shown in the
installation diagram of indoor and outdoor unit, to
prevent water coming in the outdoor unit.
4. Insulate the unused cords (conductors) from any
water coming in the outdoor unit. Proceed them so
that they do not touch any electrical or metal parts.
<Stripping length of connecting cable>
Earth line
Connecting cable
Power supply cord
Fig. 8-5-9
70
60
L
N
10
60
10
10
70
10
123
Fig. 8-5-8
LN 1 32
Terminal block
Cord clamp
Earth line
Terminal
screw
Connecting cable
Power supply cord
Cord clamp
Screw