FILE NO. SVM-02008
– 14 –
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
No. Parts name Type Specifications
1 Fan motor (for indoor) AFP-220-50-4A Output (Rated) 50W, 220-240V
2 Thermo sensor (TA-sensor) ——— 10k at 25°C
3 DC-DC transformer (T01) SWT-47 DC 390V, Secondary DC 12V, 7V
4 Microcomputer TMP87CM40AN
5
Heat exchanger sensor
——— 10k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19mH, AC0.7A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V
9 Fuse (F01) TSCR T6.3A, 250V
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6, 2W
12 Louver motor MP35EA12
Output (Rated) 2W,10poles, 1phase,
DC 12V
4-2. Outdoor Unit (RAS-18UAH-E)
No. Parts name Type Specifications
Output (Rated) 1500W, 2poles, 1phase, 220 – 240V, 50Hz
1 Compressor PH250X3-4LM Winding resistance () Red-Black White-Black
(at 20°C) 2.29 1.22
Output (Rated) 65W, 6poles, 1phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) MMF-230-65F Winding resistance () Red-Black White-Black
(at 20°C) 71.2 139
3
Running capacitor
SK45FMP02U2 AC 450V, 2µF
(for fan motor)
4
Running capacitor
SK42CMP45U1 AC 420V, 45µF
(for compressor)
5
Solenoid coil
VHV AC 220 – 240V
(for 4-way valve)
6 Thermo sensor TE / TD 10k at 25°C / 50k at 25°C
7 Relay VC20FA 220 – 240V, 50Hz, 1P1a
8 Transformer TT-05 220 – 240V
9 Microcomputer TMP47C840N
10 Varistor (R73, 74, 86) 15G471K 470V
11 Fuse (F01) MT3 T5A, 250V