FILE NO. SVM-02008
– 36 –
8-3. Installation
8-3-1. Optional installation parts
Air inlet
Drain outlet
<Fixing bolt arrangement of outdoor unit>
RAS-18UAH-E, RAS-18UA-E, RAS-18UAX, RAS-18UA-AR
Fig. 8-3-1
RAS-18UAX-T2, RAS-24UAH-E, RAS-24UA-E,
RAS-24UAX, RAS-24UA-AR, RAS-24UAX-T
Fig. 8-3-2
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
Refrigerant piping
Liquid side : 6.35 mm
Gas side : 12.70 mm (RAS-18UF)
: 15.88 mm (RAS-24UF,
RAS-18UFPX-T2)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Air outlet
Air outlet
Drain outlet
Air inlet
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use 8 mm or 10 mm anchor bolts and nuts.
If it is necessary to drain the defrost water, attach Drain nipple ! to the bottom plate of the outdoor unit
before installing it.
600 mm
325 mm
52 mm
120 mm
600 mm
340 mm
64 mm
120 mm