EasyManua.ls Logo

Toshiba RAS-18UAX - 4-4 Outdoor Unit (RAS-18 UA-AR) Electrical Parts

Toshiba RAS-18UAX
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-02008
– 17 –
4-8. Outdoor Unit (RAS-24UAX-T)
No. Parts name Type Specifications
Output (Rated) 2200W, 2poles, 1phase, 220 – 240V, 50Hz
1 Compressor PH280X3-4MS Winding resistance () Red-Black Red-Black
(at 20°C) 2.72 0.82
Output (Rated) 65W, 6poles, 1phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) KRG6-71SB5P-T Winding resistance () Red-Black White-Black
(at 20°C) 143.0 275.0
3
Running capacitor
SK45FMP3.5U2 AC 450V, 3.5µF
(for fan motor)
4
Running capacitor
SK42CMP45U1 AC 420V, 45µF
(for compressor)
5 Magnetic relay CLK-35J 220 – 240V, 50Hz

Table of Contents