EasyManua.ls Logo

Toshiba RAS-18UKPX3 - Outdoor Unit (RAS-18 UA-AR3); Outdoor Unit (RAS-18 UAX3-T2)

Toshiba RAS-18UKPX3
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
FILE NO. SVM-04008
4-8. Outdoor Unit (RAS-18UA-AR3)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH210T2-4L7 Winding resistance () C-R C-S
(at 20°C) 1.07 2.20
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T Winding resistance () Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451355KQ AC 450 V, 3.5µF
(for fan motor)
4
Running capacitor
371356JCR AC 420 V, 35µF
(for compressor)
5 Magnetic contactor CLK-26J 220 – 240 V, 50 Hz
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor 2JS350D5DA02 Winding resistance () C-R C-S
(at 20°C) 0.981 2.845
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T4 Winding resistance () Red-Black White-Black
(at 20°C) 68.15 170.50
3
Running capacitor
451205KQ AC 450 V, 2µF
(for fan motor)
4
Running capacitor
SK42CMP45U1-S AC 420 V, 45µF
(for compressor)
5 Magnetic contactor CLK-35J 220 – 240 V, 50 Hz
4.9. Outdoor Unit (RAS-18UAX3-T2)

Table of Contents

Related product manuals