– 40 –
FILE NO. SVM-04008
Air outlet
Air inlet
325 mm
600 mm
Air outlet
52 mm
120 mm
8-3. Installation
8-3-1. Optional installation parts
<Fixing bolt arrangement of outdoor unit>
RAS-24UAH-E3, RAS-24UA-E3, RAS-24UAX3, RAS-24UA-AR3, RAS-24UAX3-T, RAS-18UAX3-T2
Fig. 8-3-1
RAS-18UAH-E3 RAS-18UA-E3, RAS-18UAX3, RAS-18UA-AR3
Fig. 8-3-2 Fig. 8-3-3
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
• Use ∅8 mm or ∅10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple ! to the bottom plate of the outdoor unit
before installing it.
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
Refrigerant piping
Liquid side : ∅6.35 mm
Gas side : ∅12.70 mm (18 series except RAS-18UKPX3-T2 / RAS-18UAX3-T2)
: ∅15.88 mm (24 series and RAS-18UKPX3-T2 / RAS-18UAX3-T2)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Air inlet
Drain outlet
600 mm
120 mm
64 mm
Air outlet
340 mm
Air outlet
Air inlet
325 mm
600 mm
Air outlet
52 mm
120 mm