EasyManua.ls Logo

Toshiba RAS-24SA-ES2 - Indoor Unit (RAS-24 SKHP-ES2) Parts; Outdoor Unit (RAS-24 S2 AH-ES2) Parts

Toshiba RAS-24SA-ES2
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
FILE NO. SVM-10049
No. Parts name Type Specifications
1 Fan motor (for indoor) MF-340-30-1RT DC 340V, 30W
2 Thermo sensor (TA-sensor) ——— 10 k at 25°C
3 Switching Transformer (T01) SWT-77 DC 7V, 12V
4 Microcontroller TMP87CM40ANG-6P68
5 Heat exchanger sensor
——— 10 k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-R06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C03) EKMH451VSN121MQ35S 120 µF, 450 V
9 Fuse (F01) BET6.3A 6.3 A, 250 V
10 Varistor (R09, R10) SR561K14DO 560 V
11 Resistor (R01) RF-5TK1R8 1.8 , 5W
12 Louver motor MP24Z3T Output (Rated) 2 W, 16 poles, 4 phase,
DC 12 V
4-3. Indoor Unit (RAS-24SKHP-ES2)
4-4. Outdoor Unit (RAS-24S2AH-ES2)
No. Parts name Type Specifications
Output (Rated) 2000W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA271X3CS-4MU2 Winding resistance () Red-Black White-Black
(at 20°C) 1.27 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) FG-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 70.5 120.1
3
Running capacitor
DS451305NPQB AC 450V, 3.0µF
(for fan motor)
4
Running capacitor
B32332I5606J063 AC 450V, 60µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 ~ 240V
(for 4-way valve)
6 Thermo sensor TE / TD 10k at 25°C / 50k at 25°C
7 Magnetic contactor A35P 220 ~ 240V, 50Hz
8 Transformer TT-05 220 ~ 240V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74) 15G471K 470V
11 Fuse (F01) TSCR T6.3A, 250V

Table of Contents