10-2. Outdoor Unit
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
No. Part name Procedures Remarks
1 Common
procedure
– 72 –
FILE NO. SVM-10046
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
 
 
 
4
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) 
5 Spark killer
Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 18L)
3) Disconnect the lead wires from the terminal.
Magnetic
contactor
2) Remove the Panel front (2 screws ∅4 x 10L)
    Pressing downward and pulling out toward you.
3) Remove 2 Cord clamps (4 screws ∅4 x 16L) and
    and connecting cable after removing 5 screws on
    the terminal block and 1 ground screw on the 
    electrical parts base.
Panel-Front
screws
Ø4 x 10L
screws
Ø4 x 10L
4 screws
Ø4 x 16L
2 Cord clamps
Running capacitor
for Compressor
Running capacitor
for Fan motor
Spark killer
Magnetic contactor
Capacitor band
2 screws
Ø4 x 10L
Reactor
(RAS-24S2AH-ES2)
4 screws
Ø4 x 16L
2 Cord clamps
Running capacitor
for Compressor
Running capacitor
for Fan motor
Spark killer
Magnetic
 
contactor
Capacitor band
(RAS-24SA-ES2)
 
1)  Perform the common procedure  1
2)  Remove the fixing screw. (2 screws    4 x 10L)
3)
6 
Disconnect the housing from the P.C.Board.
 ∅
 Transformer
(Heat pump model)
 
1)  Perform the common procedure  1
2)  Disconnect the lead wires from the P.C.Board.
3)
7 
Remove P.C.Board after unhooking 4 clams.
 P.C. Board
(Heat pump model)
(Cooling model)