3
FILE NO. SVM-10049
1. SPECIFICATIONS
MODEL RAS-24SKP-ES2
RAS--24SA-ES2
ITEM
Cooling
kW
Phase
V
Hz
Power consumption W
Power factor %
Running A
Current Indoor/Outdoor
Starting current A
Moisture removal lit/h
Noise Indoor (H/M+/M/L+/L) dB
Outdoor (220-240V) dB
Refrigerant Name of refrigerant
Rated amount kg
Refrigerant control
Interconnection Gas side size mm
pipe Connection type
Liquid side size mm
Connection type
Maximum length m
(One way)
Maximum height m
difference
INDOOR UNIT
Dimensions Height mm
Width mm
Depth mm
Net weight kg
Evaporator type
Indoor fan type
Airflow volume High fan
m
3
/h
Medium fan
m
3
/h
Low fan
m
3
/h
Fan motor output W
Air filter
OUTDOOR UNIT
Dimensions Height mm
Width mm
Depth mm
Net weight kg
Condenser type
Outdoor fan type
Airflow volume
m
3
/h
Fan motor output W
Compressor Model
Output W
Safety device
Louver type
Usable outdoor temperature range °C
4200
15 ~ 43
RAS-24SKP-ES2
25*
2
10
57
15*
1
2070
97
0.3/9.1 0.3/8.6
1
220 - 240
50
Capacity
Power source
220V
6.80
240V
6.85
2030
98
2.7
55
50/48/46/43/40
56
R410A
1.90
Capillary tube
12.7
Flare connection
6.35
Flare connection
Fuse , IOL
320
1050
228
13
Finned tube
Cross flow fan
1240
1000
850
30
Honeycomb woven filter with PP frame
RAS-24SA-ES2
Finned tube
890
900
320
59
Propeller fan
4000
Automatic louver
85
PA271X3CS-4MUL
2000
Note *1 Chargeless pipe
*2 Maximum pipe

Table of Contents

Related product manuals