EasyManua.ls Logo

Toshiba RAS-M10U2KCVG-SG1 x5 - Control Block Diagram

Toshiba RAS-M10U2KCVG-SG1 x5
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit (Inverter Assembly)
A unit P.M.V.
Inverter outdoor frequency control
A/D converter function
P.M.V. control
Processing (Temp. processing)
Error display
Serial signal communication with indoor unit
Signal communication with main P.C. board
Function select
M.C.U
Discharge temp. sensorGas side pipe temp. sensor
Outdoor air temp. sensor
WP-041 (CONTROL P.C. B)
MCC-1571 (MAIN P.C. B)
220–240V ~50Hz
220V ~60Hz
Driver
circuit of
P.M.V.
B unit P.M.V.
C unit P.M.V.
D unit P.M.V.
E unit P.M.V.
Function select
P.M.V : Pulse motor valve
PWM : Pulse width modulation
IPM : Intelligent power module
Signal communication
Noise filter
High power factor
correction circuit
Converter
(AC → DC)
Gate drive
circuit
Inverter
(DC → AC)
Output current
sensor
Output current
sensor
Input current
sensor
E unit serial signal
communication circuit
D unit serial signal
communication circuit
C unit serial signal
communication circuit
B unit serial signal
communication circuit
A unit serial signal
communication circuit
Gate drive
circuit
Inverter
(DC → AC)
Signal communication with
control P.C. board
M.C.U 2
M.C.U 1
Compressor
Outdoor
fan motor
PWM synthesis function
Input current release control
IPM over current detect control
High power factor correction control
Signal communication with
control P.C. board
Fan motor control
Compressor motor control
High pressure protective operation.
Case thermostat operation.
Clock frequency
oscillator circuit
20 MHz
Clock frequency
oscillator circuit
8 MHz
High-pressure switch
Case thermo
8. CONTROL BLOCK DIAGRAM
- 31 -