C. Sensor, current, compressor operation frequency, PMV opening, Miswiring (mispiping) check display
Using the service display function, you can check a variety of information.
(Note 1) Basically carry out the service switch settings while the machine stops. If carry out during the operation,
the pressure may change suddenly and a danger may grow.
:ON (*:3 sec ON/0.5 sec OFF):OFF
◎:Rapid Flashing(5 times/sec) ◇:Slow Flashing(1 time/sec)
display Contents
No.
D800 D801 D802 D803 D804 D805 Temp. sensor Current
(YL) (YL) (YL) (YL) (YL) (GN) (˚C) (A)
0 ●●●●● -26 or less 00.9 04.9 019 No error
1 ○●●●● -25-21 11.9 59.9 2039 Trouble in unit A
2 ●○●●● -20-16 22.9 1014.9 4059 Trouble in unit B
3 ○○●●● -15-11 33.9 1519.9 6079 Trouble in unit A and B
4 ●●○●● -10-6 44.9 2024.9 8099 Trouble in unit C
5 ○●○●● -5-1 55.9 2529.9 100〜119 Trouble in unit A and C
6 ●○○●● 04 66.9 3034.9 120〜139 Trouble in unit B and C
7 ○○○●● 59 77.9 3539.9 140〜159 Trouble in unit A,B and C
8 ●●●○● 1014 88.9 4044.9 160〜179
9 ○●●○● 1519 99.9 4549.9 180〜199
10●○●○● 2024 1010.9 5054.9 200〜219
11○○●○● 2529 1111.9 5559.9 220〜239
12●●○○● 3034 1212.9 6064.9 240〜259
13○●○○● 3539 1313.9 6569.9 260〜279
14●○○○● 4044 1414.9 7074.9 280〜299
15○○○○● 4549 1515.9 7579.9 300〜319
16●●●●○ 5054 1616.9 8084.9 320〜339
17○●●●○ 5559 1717.9 8589.9 340〜359
18●○●●○ 6064 1818.9 9094.9 360〜379
19○○●●○ 6569 1919.9 9599.9 380〜399
20●●○●○ 7074 2020.9 100〜104.9 400〜419
21○●○●○ 7579 2121.9 105〜109.9 420〜439
22●○○●○ 8084 2222.9 110〜114.9 440〜459
23○○○●○ 8589 2323.9 115〜119.9 460〜479
24●●●○○ 9094 2424.9 120〜124.9 480〜499
25○●●○○ 9599 2525.9 125〜129.9 500
26●○●○○ 100〜104 26〜26.9 130〜134.9 -
27○○●○○ 105〜109 27〜27.9 135〜139.9 -
28●●○○○ 110〜114 28〜28.9 140〜144.9 -
29○●○○○ 115〜119 29〜29.9 145〜149.9 -
30●○○○○ 120 or more 30〜30.9 150〜154.9 -
31○○○○○ Sensor error31 or more155〜 or more -
Miswiring
(mispiping) check
Compressor
frequency (rps)
PMV opening
(pls)
Trouble in unit D
Trouble in unit A and D
Trouble in unit B and D
Trouble in unit A,B and D
Trouble in unit C and D
Trouble in unit A,C and D
Trouble in unit B,C and D
Trouble in unit A,B,C and D
Trouble in unit E
Trouble in unit A and E
Trouble in unit B and E
Trouble in unit A,B and E
Trouble in unit C and E
Trouble in unit A,C and E
Trouble in unit B,C and E
Trouble in unit A,B,C and E
Trouble in unit D and E
Trouble in unit A,D and E
Trouble in unit B,D and E
Trouble in unit A,B,D and E
Trouble in unit C,D and E
Trouble in unit A,C,D and E
Trouble in unit B,C,D and E
Trouble in unit A,B,C,D and E
- 43 -

Related product manuals