1. In the initial LED display status, Green LED(D805) is lighted as below.
2. If there is an error, Yellow LED are lighted according to the error as described in the below table.
3. When there are two or more errors, LEDs flash cyclically.
4. When D804 or D805 are flashing (rapid or slow), push and hold SW801 and SW802 simultaneously
for 5 seconds or more. (Display returns to the error display.)
Normal
D800 D801 D802 D803 D804 D805
(Yellow) (Yellow) (Yellow) (Yellow) (Yellow) (Green)
●●●●●○
○:ON ●:OFF
Error occurring
D800 D801 D802 D803 D804 D805
(Yellow) (Yellow) (Yellow) (Yellow) (Yellow) (Green)
●/○* ●/○* ●/○* ●/○* ●/○* ○
○:ON ○*:3 sec ON/0.5 sec OFF ●:OFF
○:ON (○*:3 sec ON/0.5 sec OFF)●:OFF
Display Indoor Description
D800 D801 D802 D803 D804 D805 check code
(YL) (YL) (YL) (YL) (YL) (GN)
● ● ● ● ● - Normal operation (no error)
○* ● ● ● ● 1C Compressor case thermostat error
● ○* ● ● ● 21 High pressure switch error
○* ○* ● ● ● 1C Compressor system error
●●○*●
●
1d
Compressor lock
○* ● ○* ● ● 1F Compressor breakdown
● ○* ○* ● ● 14 Driving element short circuit
○* ○* ○* ● ● 16 Position detection circuit error
● ● ● ○* ● 17 Current detection circuit error
○* ● ● ○* ● 1C Communication error between MCU
● ○* ● ○* ● 1A Fan system error
○* ○* ● ○* ● 1E Discharge temperature error
● ● ○* ○* ● 19 Discharge temperature sensor (TD) error
○* ● ○* ○* ●
1b
Outdoor air temperature sensor (TO) error
● ○* ○* ○* ● 18 Suction temperature sensor (TS) error
○* ○* ○* ○* ● 18 Heat exchanger temperature sensor (TE) error
● ● ● ● ○* 1C Gas pipe (unit A) temperature sensor (TGa) error
○* ● ● ● ○* 1C Gas pipe (unit B) temperature sensor (TGb) error
*1
*2
*2
*2
*2
*2
● ○* ● ● ○* 1C Gas pipe (unit C) temperature sensor (TGc) error
○* ● ○* ● ○* - PMV error (SH≥20)
● ○* ○* ● ○* - PMV error (SH≤–8)
● ● ● ○* ○* 20 PMV leakage error (unit A)
○* ● ● ○* ○* 20 PMV leakage error (unit B)
● ○* ● ○* ○* 20 PMV leakage error (unit C)
○* ● ○* ○* ○* - Miswiring (mispiping) check error
∗1: Back-up operation is performed without error display of the indoor unit.
∗2: Operated normally when the air conditioners in other rooms are driven.
○
● ○* ○*
1C Communication error between MCU
○*
○* ○* ○*
○*
1C Communication error between MCU
• The D800 LED represents unit A.
• The D801 LED represents unit B.
• The D802 LED represents unit C.
• The D803 LED represents unit D.
• The D804 LED represents unit E.
11-6. Trouble Diagnosis by Outdoor LED
For the outdoor unit, the self-diagnosis is possible by LED (Green) and five LEDs (Yellow).
Green LED (D805) and Yellow LEDs (D800 to D804) are provided on the display P.C. board WP-041.
○* ● ● ○* 1C
Gas pipe (unit D) tempe
rature senso
r (TG
d
)
error
○*
○* ● ○* ○* 20
PMV leakage error (unit D)
○*
● ● ○*
● ○* 1C
Gas pipe (unit E) temperature sensor (TGe) error
● ● ○* ○*
○*
20
PMV leakage error (unit E)
○*
○*