NOTE
At working time (finish time), be sure not to
damage the cover of the sensor lead wire with
edge of sheet metal, etc.
If the cover of the sensor lead wire is
damaged, it is dangerous because an electric
shock or fire may be caused.
NOTE
After replacing of parts, check the sensors are
mounted at the specified positions.
If there are incorrect mounted positions,
control of the product does not operate
correctly and a trouble may be caused.
TD sensor
(Discharge
temperature)
∗ Attachment
Mount TD sensor on the straight part of the discharge pipe
so that the lead wire directs upward and the sensor directs
upward of the cabinet.
TO sensor
(Outside
temperature)
∗ Attachment
Insert TO sensor holder claw into the heat exchange
terminal block hole and then mount it.
No. Part name Procedure Remarks
NOTE
NOTE
Detail B
Detail C
Heat exchange
terminal block hole
TO sensor
holder
13
14
Detail B
Detail C