6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E
6-2. Outdoor Unit
RAS-5M34UAV-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Parts name
Compressor
Outdoor fan motor
Reactor
Reactor
4-way valve coil
PMV coil
P. C . board (Main PCB)
P. C . board (Control PCB)
P. C . board (Fan motor connection)
Fuse (Mounted on P. C . board MCC-1571)
Fuse (Mounted on P. C . board MCC-1571)
Fuse (Mounted on P. C . board MCC-1571, MCC-5071)
Outdoor temp. sensor (TO sensor)
Evaporator temp. sensor (Te sensor)
Discharge temp. sensor (Td sensor)
Suction temp. sensor (Ts sensor)
Temp. sensor at A room gas side (TGa-sensor)
Temp. sensor at B room gas side (TGb-sensor)
Temp. sensor at C room gas side (TGc-sensor)
Temp. sensor at D room gas side (TGd-sensor)
Temp. sensor at E room gas side (TGe-sensor)
Compressor ther mo.
Ter minal block (9P)
Model name
DA270A2F-20L
ICF-280-A100-1 (A)
CH-56
CH-76
VHV-H
UKV-A
MCC-1571
MCC-5071
MCC-1436
—
—
—
—
—
—
—
—
—
—
—
—
US-622
—
Rating
—
Output 100 W
5.8 mH, 18.5 A
9.9 mH, 1 A
AC 200–240 V
DC 12 V
AC 220–240 V
AC 220–240 V
AC 220–240V
AC 250V, 25 A
AC 250V, 10 A
AC 250V, 3.15 A
10 k: (25°C)
10 k: (25°C)
50 k: (25°C)
10 k: (25°C)
10 k: (25°C)
10 k: (25°C)
10 k: (25°C)
10 k: (25°C)
10 k: (25°C)
ON: 90°C, OFF: 125°C
AC 250 V, 20 A
No.
1
2
3
4
5
6
7
Parts name
Fan motor (for indoor unit)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor (TCj-sensor)
Humidity sensor
Louver motor (Right, Left, Horizontal)
Louver motor (Moving panel)
Type
E: ICF-340-30-4
ND: ICF-340-30-4A
( – )
( – )
( – )
C7-M3R-TC2
MP24Z3N
MP24Z4N
Specifications
DC 280–340 V, 30 W
10 k: at 25°C
10 k: at 25°C
10 k: at 25°C
31 k:, 60 % RH
Output (Rated) 1 W, 16 poles, DC12 V
Output (Rated) 1 W, 16 poles, DC12 V