EasyManua.ls Logo

Toshiba RAS-M16PKVP-E - In Cooling Operation; Indoor Fan Motor Control

Toshiba RAS-M16PKVP-E
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 53 –
+2.5
Ta
[
°C
]
+2.0
+1.5
+1.0
+0.5
Ts c
a
b
c
d
e
M+(WC)
*3
*4
*5
L(W7)
Fan speed
H (WD)
*6
*7
*8
L+(W8)
Hi Power
L
L+
M
M+
H
W8
(L + M) / 2
WC
(M + H) / 2
WE
Indication
Hi Power
W7
(L + M) / 2
WA
(M + H) / 2
WD
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed = (M + –L) × 3/4 + L
*4 : Fan speed = (M + –L) × 2/4 + L
*5 : Fan speed = (M + –L) × 1/4 + L
*6 : Fan speed = (H –L+) × 3/4 + L+
*7 : Fan speed = (H –L+) × 2/4 + L+
*8 : Fan speed = (H –L+) × 1/4 + L+
(Linear approximation from M+ and L)
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase
control induction motor.
The fan rotates in 5 stages in MANUAL mode, and in 5
stages in AUTO mode, respectively. (Table 1)
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate (Cooling, Dry)
Description
* Symbols
UH : Ultra High
H : High
M+ : Medium+
M : Medium
L+ : Low+
L : Low
L- : Low–
UL : Ultra Low
SUL : Super Ultra Low
The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When the fan speed mode is
manual and TA < 22°C and the
compressor stops, the fan speed
is controlled from W2
(20 seconds) to 0 rpm
(40 seconds).
3) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
4) When the fan speed mode is
AUTO and the compressor stops,
the fan speed is controlled from
W2 (20 seconds) to 0 rpm
(40 seconds).
Fan speed level
WF
WE UH
WD H
WC M+
WB
WA M
W9
W8 L+
W7 L
W6 L–
W5 UL
W4
W3 SUL
W2
W1
RAS-M10PKVP-E
Fan speed Air flow rate
(rpm) (m
3
/h)
1200 690
1200 690
1140 640
1080 600
1020 560
960 510
910 480
850 430
790 390
770 370
700 320
650 290
600 250
600 250
520 190
RAS-M13PKVP-E
Fan speed Air flow rate
(rpm) (m
3
/h)
1260 730
1260 730
1210 690
1130 640
1060 590
990 530
930 490
870 450
810 400
770 370
700 320
650 290
600 250
600 250
520 190
RAS-M16PKVP-E
Fan speed Air flow rate
(rpm) (m
3
/h)
1340 790
1340 790
1280 750
1200 690
1120 630
1040 570
980 530
930 490
880 450
770 370
700 320
650 290
600 250
600 250
520 190
RAS-M18PKVP-E
Fan speed Air flow rate
(rpm) (m
3
/h)
1450 845
1450 845
1390 805
1310 745
1220 680
1130 620
1070 575
1000 525
930 475
800 380
700 310
650 275
600 240
600 240
520 185