– 79 –
10-3-4. Wiring Connection
K Connecting cable
Wiring the connecting cable can be carried
out without removing the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it
toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (or as according
to local regulations/codes) into the pipe hole
on the wall.
4. Pull the connecting cable through the cable
slot on the rear panel so that it protrudes
about 15 cm out of the front.
5. Insert the connecting cable fully into the
terminal block and secure it tightly with
screws.
Make a loop with the earth wire under the
terminal block and secure it with the earth
screw.
6. Tightening torque: 1.2 N•m (0.12 kgf•m)
7. Secure the connecting cable with the cord
clamp.
8. Attach the terminal cover and moving panel
on the indoor unit.
CAUTION
Be sure to refer to the wiring system diagram
labelled inside the front panel.
Check local electrical regulations for any specific
wiring instructions or limitations.
Fig. 10-3-6
Fig. 10-3-7
Fig. 10-3-8
Fig. 10-3-9
NOTE
Connecting cable (Indoor unit/outdoor unit)
Wire type: H07RN-F or 60245IEC66 (1.0 mm²)
S
c
r
e
w
C
o
nnecting cable
Cord clam
p
T
e
r
m
i
n
l
c
o
v
r
T
e
rminal block
E
a
rth wire
S
c
r
e
w
T
e
rmin
a
l
b
lo
ck
Earth wire
(
loo
p)
E
a
rth
sc
r
ew
Connectin
g
cabl
e
ab
out 1
5
c
m
10 mm
110 mm
10 mm
50 mm
Earth line

Table of Contents

Related product manuals