4 Timer operation 5  Adjustment of wind direction
For best cooling and heating performance, adjust the 
louvers (adjustment plates of up / down wind direction) 
appropriately. Cold air descends and warm air rises, so 
to heat a room tilt the louvers downward, and to cool a 
room tilt them horizontally.
 CAUTION
Direct the louvers horizontally for cooling. 
If the louvers stay pointed downward during cooling, 
condensation may form on the discharge port and / 
then drops from the louvers.
•  When operation is stopped, the horizontal louver 
(plate for adjusting the vertical air fl ow) automatically 
closes.
•  In heating preparation mode, the horizontal louver 
(plate for adjusting the vertical air fl ow) points 
upward. The louver starts swinging when the heating 
preparation mode has fi nished, but the swing 
indicator appears on the remote controller even in 
heating preparation mode.
As characteristics of air, cold air 
accumulates lower area and warm 
air accumulates upper area.
To set the louver direction and auto swing
1
Push the Menu button several times and select 
the wind direction mode to blink the wind 
direction.
2
Push the setting button several times to display 
the louver direction as shown in the figure below.
•  If you do not push any button for 30s, the wind 
direction mode finishes.
 For heating
The louver can be adjusted to six steps.
Point the louver downward. If not pointing downward, 
hot air may not reach the floor.
Initial (1) (2) (3) (4) (5) (6)
(Swing)
Operation mode Available directions
HEAT, FAN (1) ↔ (2) ↔ (3) ↔ (4) ↔ (5) ↔ (6)
 For cooling
The louver can be adjusted to four steps.
Point the louver horizontally. If pointing downward, dew 
may form on the surface of the air discharge port and 
may drop down.
If a louver lock setup is carried out in the position of 
(1), fan speed will be restricted for prevention of ceiling 
contamination.
Initial (1) (2) (3) (4)
(Swing)
Operation mode Available directions
COOL, DRY (1) ↔ (2) ↔ (3) ↔ (4)
4.1 Timer off Operation
Timer off: When reaching the setting time, the indoor unit stops running.
1
Timer off button
Press the timer off button in process of air conditioner operation.
• The   and   light, while   and timing indication icon fl icker.
2
Select the timer off time
Press the set button to set the time.
•  Increase in accordance with the law of 0.5 hour(30 minutes), 1 hour, 2 hours ..., it can be up to 24 hours.
•  If you do not operate the button within 30 seconds, the timer off setting will be canceled.
3
Press the timer off button
The   disappears and the timer off indication icon changes from fl ickering to normally on, then the timer off 
function starts.
When running the shutdown timer, the timing indication is displayed in the form of countdown.
 ■
Cancel timing
1
Press the timer off button.
The timing indication icon disappears.
NOTE
•  When the shutdown timer is running, it will continue to run even if the air conditioner is turned on or off via the 
on/off button.
– 10 – 
19-EN  20-EN