The items described on the inverter, the resolver option and their instruction manuals are very important so that you can use
safely the inverter and resolver option, prevent injury to yourself and other people around you as well as to prevent damage
to properly in the area.
Read the instruction manual (E6582062) attached to the inverter to understand the safety precautions, thoroughly
familiarize yourself with the symbols and the indications completely and then continue to read the manual. Make sure that
you observe all warnings given.
Explanation of markings
Meanings of symbols
Safety precautions
Marking Meaning of marking
WARNING
Indicates that errors in operation will lead to death or serious injury.
CAUTION
Indicates that errors in operation will lead to injury
*1
to people or that these errors will cause
damage to physical property
*2
.
*1 Such things as injury, burns or electric shock that will not require hospitalization or long periods of outpatient treatment.
*2 Physical property damage refers to wide-ranging damage to assets and materials.
Marking Meaning of marking
Indicates an inhibition (Don't do it).
Detailed information on the inhibition is described in illustration and text in or near the symbol.
Indicates a mandatory action that must be followed.
Detailed information on the mandatory action is described in illustration and text in or near the
symbol.
Indicates a warning or caution.
Detailed information on the warning or caution is described in illustration and text in or near
the symbol.

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)