Notes on operation
If no history information is stored, this parameter is skipped and the next parameter “aua” is displayed.
head and end are added respectively to the first and last parameters in a history of changes.
Note: The following parameters are not displayed in this auh, even if they are the most recent changes.
fc (Operation frequency of operation panel), auf (Guidance function),
aul (Overload characteristic selection), au1 (Automatic acceleration/deceleration),
au2 (Torque boost setting macro function), typ (Default setting),
set (Checking the region setting), f700 (Parameter protection selection) ,
f737 (All key operation prohibition ) , f738 (Password setting (f700)) ,
f739 (Password verification)
6.1.2 Application easy setting (aua)
aua : Application easy setting
[Parameter setting]
Title Function Adjustment range Default setting
aua
Application easy setting
0:-
1: Initial easy setting
2: Conveyor
3: Material handling
4: Hoisting
5: Fan
6: Pump
7:Compressor
0
Application easy setting (aua):
Parameters necessary to your machine can be set easily using the application easy setting.
The parameters necessary to the machine is set to easy setting mode parameters 1-32 (f751-f782). Set the
parameters using the easy setting mode. (Refer to section 4.5.)