Conducted TX (Transmit) Power tolerances
Parameter Cond. tr. p. Notes
LTE
LTE Band 1, 3, 5, 8, 18,
19,21,28,39 +23 dBm +- 1 dB
LTE Band 7, 38, 40, 41 +22 dBm +- 1 dB
UMTS
Band 1 (IMT 2100 12.2 kbps)
Band 5 (UMTS 850 12.2 kbps)
Band 6 (UMTS 850 12.2 kbps) +23 dBm +- 1 dB Connectorized (Class 3)
Band 8 (UMTS 900 12.2 kbps)
Band 9 (UMTS 1700 12.2 kbps)
Band 19 (UMTS 850 12.2 kbps)
TD-SCDMA
Band 39 +23 dBm +- 1 dB
WLAN
IEEE 802.11 b/g/n, max. 150 Mbps
WEP, WPA-PSK, WPA2-PSK, WPA-PSK/WPA2-PSK Mixed, WPA-EAP, WPA2-EAP
TKIP/AES encryption
Frequency 2.412 – 2.462 GHz, 11 channels
Output power 20 dBm max
I/O Specification
2 x digital inputs, galvanic isolation, current limited to 5mA, voltage 0 - 32V
nominal, input voltage of 0-5V is interpreted as ‘0’, input voltage over 12V is
interpreted as ‘1’
2 x digital outputs, type: transistor sourcing, output voltage 24V DC +/- 5%
nominal
1 x 24V DC out: 24V DC +/- 5% nominal, always active, non-configurable
Total combined maximum current output for digital outputs and 24V DC out is
limited to 50mA
Software Configurable I/O state
Powering requirements
12-48V DC +/-20%, 10.0W max, reverse polarity protected