A. INTRODUCTION
1. Congratulations: Thank you for purchasing TPI products. The 608(BT) is easy to
use and built to last. Please remember to complete product warranty registration on
our website at www.tpieurope.com.
2. Product Description: The 608(BT) digital manometer measures pressure or
vacuum in four units of measure. Please follow manufactures recommendations on
all equipment being serviced with the 608(BT).
B. SAFETY CONSIDERATIONS
1. Wear safety goggles.
2. Make sure system pressure does not exceed the capability of the 608(BT) before
connection.
3. Check all connections making sure they are secure with no leaks.
4. Observe all manufacturers recommendations.
C. General Specifications
Sensor Type Temperature compensated solid state
Connector Type Standard 1/4” Barb Fitting
Range -150 mBar to + 150 mBar
Units of Measure PSI, mBar, KPa, inH
2
O
Over Pressure +/- 300 mBar
Operating Temperature -10° to 50°C (14° to 122°F)
Power Supply 9 Volt Alkaline
D. Accuracy
Measurement Range Resolution Accuracy
inH
2
O +/-(0.01 to 29.99) 0.01 +/- 0.3 inH
2
O
+/-(30.0 to 60.0)
0.1 +/- 0.6 inH
2
0
mbar
+/-(0.01 to 29.99) 0.01 +/- 0.3 mbar
+/-(30.0 to 150.0) 0.1 +/- 1.5 mbar
KPa
+/-(0.001 to 2.999) 0.001 +/- 0.03 KPa
+/-(3.00 to 15.00) 0.01 +/- 0.15 KPa
PSI +/-(0.001 to 2.175) 0.001 +/- 0.021 PSI
1