e. When measuring in chemically treated wood, con-
sider the effects chemical treatment may have on
readings. It may not be possible to consider the read-
ings as quantitative measurements, but as qualita-
tive comparisons. A known dry sample can be used as
the comparative reading to refer to.
f. It is advised to not slide the meter across the
surface under test. Place the meter on the surface,
record the reading, lift and repeat.