Checking the Installation
• All holes should be sealed with silicone or foam.
• Check with a sheet of paper that the fans blow in the right direction.
• The drain circuit should be slanted on all evaporators and the moisture trap should be installed.
• The hole should be located at the expansion valve on all evaporators.
• The temperature sensor should be connected on all evaporators.
• The in-cab control box should be located in a spot that it is accessible and visible from the driver’s position.
• The contact draw should be made.
• Hoses should not be taut (they should be able to absorb vibrations and be shortened in case of leaks).
• Hoses should not rub against moving parts, sharp parts, or parts that can reach high temperatures.
• The oil return should be connected.
• The fluid injection hole should be properly located (R-404A/R-452A units only).
• The compressor should be primed with oil.
• The unit should be connected to the battery.
• The drive kit test should have been carried out.
• The seal test should have been carried out.