MS-SVN056C-EN 33
Outdoor Unit Installation
Concrete base
Mounting base should be 100-300mm/3.94- 11.81 in height above the ground.
Install a draining opening around the mounting base.
Install the unit to the base with M10 anchor bolts.
In installations on the roof or balcony, avoid draining the unit towards areas of human crossing.
100
3.94in
100300
3.94~11.81in
No Description
Outdoor unit
Rubber protection against vibrations
M10 anchor bolt
Drain (Width 100/3.94in x depth150/5.9in)
Drain
Orifice (ĭ100/3.94in x depth 150/5.9in)