EasyManua.ls Logo

Trane 824 Comfort Control - Page 22

Trane 824 Comfort Control
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Guide
page 22 18-HD72D1-1
5.3.2 Group 2 Equipment Settings
MENU ITEM OPTIONS [DEAFULT] DESCRIPTION
Compressor Cooling Cycles Per Hour 2 - 6 [3] Select the number of cycles per hour during cooling operation
1st Stage Compressor Cooling Cycles Per Hour 2 - 6 [3]
Select the number of cycles per hour during 1st stage cooling
operation
2nd Stage Compressor Cooling Cycles Per Hour 2 - 6 [3]
Select the number of cycles per hour during 2nd stage cooling
operation
Compressor Heating Cycles Per Hour 2 - 6 [3] Select the minimum runtime (MRT) of stage 1 indoor heat
1st Stage Compressor Heating Cycles Per Hour 2 - 6 [3] Select the minimum runtime (MRT) of stage 2 indoor heat
2nd Stage Compressor heating Cycles Per Hour 2 - 6 [5] Select the minimum offtime (MOT) for indoor heat operation
Indoor Heater Cycles Per Hour 2 - 6 [5] Select the number of cycles per hour during indoor heat operation
1st Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 1st stage indoor heat
operation
2nd Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 2nd stage indoor heat
operation
3rd Stage Indoor Heat Cycles Per Hour 2 - 6 [5]
Select the number of cycles per hour during 3rd stage indoor heat
operation
5.3.3 Group 3 Sensors Settings
MENU ITEM OPTIONS [DEFAULT] DESCRIPTION
Select Outdoor Temperature Sensor
[No ODT Sensor],
Thermostat ODT Sensor
Select whether an outdoor temperature sensor has been connected
Calibrate Outdoor Temperature Sensor -5°F - 5°F Calibrate the outdoor temperature sensor
Select Indoor Temperature Sensor
[Thermostat IDT Sensor]
Wired IDT Sensor
Select whether the indoor temperature is being sensed by the thermostat
onboard sensor or wired remote sensor
Calibrate Indoor Temperature Sensor -5°F - 5°F Calibrate the indoor temperature sensor
Calibrate Onboard Humidity Sensor -5% - 5% Calibrate the onboard humidity sensor
Thermostat Humidity Sensor
[Disable],
Enable
Select whether to use the onboard humidity sensor when a wired indoor
remote temperature sensor is being used