88-A4HP4001-1G-EN 27
TAM9A0B30V31 TAM9A0B30V31
Cooling @ 900 SCFM Heating @ 850 SCFM
LIQUID PRESSURE (PSIG)
LIQUID PRESSURE (PSIG)
SUCTION PRESSURE (PSIG)
SUCTION PRESSURE (PSIG)
110
115
120
125
130
135
140
145
150
155
160
165
170
40 50 60 70 80 90 100 110 120
170
220
270
320
370
420
470
520
40 50 60 70 80 90 100 110 120
(1)
(1)
(3)
(3)
(5)
(4)
(2)
(2)
INDOOR ENTERING
WET BULB CURVES
TOP TO BOTTOM
71, 67, 63 AND 59 DEG F.
INDOOR ENTERING
WET BULB CURVES
TOP TO BOTTOM
71, 67, 63 AND 59 DEG F.
30
40
50
60
70
80
90
100
110
120
130
140
-5 5 152535455565
200
250
300
350
400
450
500
-5 5 152535455565
INDOOR ENTERING
DRY BULB CURVES
TOP TO BOTTOM 80, 70,
AND 60 DEG F.
INDOOR ENTERING
DRY BULB CURVES
TOP TO BOTTOM 80, 70,
AND 60 DEG F.
OUTDOOR TEMPERATURE (Degree F)
OUTDOOR TEMPERATURE (Degree F)
PRESSURE CURVES FOR A4HP4018D1
DWG.NO. A4HP4018D1
TAM9A0B30V31 TAM9A0B30V31
Cooling @ 900 SCFM Heating @ 850 SCFM
LIQUID PRESSURE (PSIG)SUCTION PRESSURE (PSIG)
110
115
120
125
130
135
140
145
150
155
160
165
170
40 50 60 70 80 90 100 110 120
170
220
270
320
370
420
470
520
40 50 60 70 80 90 100 110 120
(1)
(1)
(3)
(3)
(5)
(4)
(2)
(2)
INDOOR ENTERING
WET BULB CURVES
TOP TO BOTTOM
71, 67, 63 AND 59 DEG F.
INDOOR ENTERING
WET BULB CURVES
TOP TO BOTTOM
71, 67, 63 AND 59 DEG F.
30
40
50
60
70
80
90
100
110
120
130
140
-5 5 152535455565
200
250
300
350
400
450
500
-5 5 152535455565
INDOOR ENTERING
DRY BULB CURVES
TOP TO BOTTOM 80, 70,
AND 60 DEG F.
INDOOR ENTERING
DRY BULB CURVES
TOP TO BOTTOM 80, 70,
AND 60 DEG F.
LIQUID PRESSURE (PSIG)SUCTION PRESSURE (PSIG)
OUTDOOR TEMPERATURE (Degree F)
OUTDOOR TEMPERATURE (Degree F)
PRESSURE CURVES FOR A4HP4024D1
DWG.NO. A4HP4024D1