Installation
Operation
Maintenance
Quantum Climate Changer™ Air Handlers
Model : CLCP
Euro 25, CLCP Euro 50, CLCP Euro XP
Airflow Range : 1000 ~ 65,000 CFM (0.5 ~ 31 m³/s)
October 2018
IND-SVN01A-E4
Question and Answer IconNeed help?

Do you have a question about the Trane CLCP Euro XP and is the answer not in the manual?

Trane CLCP Euro XP Specifications

General IconGeneral
BrandTrane
ModelCLCP Euro XP
CategoryAir Handlers
LanguageEnglish

Summary

Introduction and Safety Information

Safety Advisories Defined

Defines three types of safety advisories: WARNING, CAUTION, and NOTICE.

Responsible Refrigerant Practices

Emphasizes responsible refrigerant handling and technician certification.

Model Number Description

Receiving and Storage

Unit Identification (Nameplate)

Explains the importance of the unit nameplate for identification and service.

Shipping Damage Resolution

Provides steps to report and resolve shipping damage claims.

Rigging and Handling Procedures

Safe Lifting Procedures

Provides instructions and warnings for safely rigging and lifting the unit.

Off Loading Procedures

Specific methods for safely offloading the unit.

Unit Placement and Assembly

Foundation Preparation

Guidelines for preparing the site and foundation for unit placement.

Installation Procedures

Duct Connections

Standards and practices for connecting air ducts to the unit.

Assembly & Installation - Joining Methods

Breakpoint Joining Method

Details the method for joining module sections at a breakpoint.

Frame to Frame Assembly (CLCP EURO 25)

CLCP EURO 25 Frame Joining

Instructions for joining CLCP EURO 25 frame sections.

Panel to Frame Assembly (CLCP EURO 25)

CLCP EURO 25 Panel Joining

Instructions for joining CLCP EURO 25 panel to frame sections.

Frame to Frame Assembly (CLCP EURO 50)

CLCP EURO 50 Frame Joining

Instructions for joining CLCP EURO 50 frame sections.

Panel to Frame Assembly (CLCP EURO 50)

CLCP EURO 50 Panel Joining

Instructions for joining CLCP EURO 50 panel to frame sections.

Unit Paneling and Assembly

Wedge Removal and Insertion

Methodology for removing and inserting panel wedges.

Personal Protection Equipment

Lists required personal protective equipment for handlers.

XP Breakpoint Internal Joints

Internal Joint Type 1

Steps for internal joint assembly for CLCP EURO XP (Type 1).

Standard to Wider Section Joint Type 2

Steps for internal joint assembly of standard to wider sections (Type 2).

Standard to Wider Section Joint Type 3

Steps for internal joint assembly of standard to wider sections (Type 3).

CKD Jobsite Assembly

Air Tight Sealing Work

Method for air-tight sealing work for CKD units at the jobsite.

Unit Joining Methods

Vertical Unit Joining

Method for joining vertical unit sections.

Final Filter Joining

Method for joining final filter sections.

Unit Component Installation

Damper Installation

Details the installation procedure for dampers.

Motor and Bracket Procedures

Motor Removal and Replacement

Steps for removing and replacing the motor in specific models.

Shipping Bracket Removal

Procedure for removing shipping brackets from the non-drive side.

Piping and Condensate Management

Condensate Drain Pan Connection

Instructions for connecting the condensate drain pan to a trap.

Piping and Connections

Chilled Water Coil Piping

Recommendations for connecting chilled water piping to coils.

Steam Coil Piping

Type A, AA Steam Coil Installation

Details for piping Type A and AA steam coils, including limits.

Unit Start-Up Procedures

Maintenance Schedule

Recommended Maintenance Intervals

Trouble Analysis

Troubleshooting Specific Issues

Pulley and Belt Troubleshooting

Motor Wiring Diagrams

VFD Wiring and Configuration

VFD Operation Settings

Pre-Start Up Checklist