Installation
Location
The 1040 is designed for installation in climate
controlled living spaces when applied with Trane’s
ComfortLink II zone control system. Place the zone
sensor in a central location with good circulation.
For proper temperature sensing, avoid exposing the
1040 to heat radiated from lamps, sun light, replaces
or any other radiant heat source.
Avoid locations close to windows, behind doors or
alcoves with poor air circulation, adjoining outside
walls, or doors that lead to the outside.
Select a location that prevents the 1040 from being
directly exposed to air currents from supply registers or
ceiling fans.
Installation Figure 1
Natural heat dissipation
from the Touch Screen
Onboard
Thermistor
Sensor
5 FEET
2 FEET
Zone
Floor
Vent
Window
Celing
Optimum
Correct
Placement
Zone
Sensor